Tbl. 8:
Technical data, solenoid valve for gas ballast valve
5.6.2 Solenoid valve for gas ballast valve (C version)
1
2
6
7
5
3
4
9
10
8
Fig. 16:
Solenoid valve connection for gas ballast valve (C version)
1
Hose nozzle
6
Small flange
2
O-ring
7
Centering ring
3
Flange
8
Circlip
4
Dosing screw
9
Solenoid valve
5
O-ring
10
Protective cap
Required tools
● Open-end wrench, 17 mm
Installing conversion kit with solenoid valve
1. Unscrew the hose nozzle from the flange and remove the O-ring.
2. Screw the small flange with O-ring into the gas ballast valve flange.
3. Install the solenoid valve with centering ring and circlip.
4. Open dosing screw by rotating to the left up to the stop.
5. Remove protective cap.
6. Establish the electrical connection.
7. Install the protective cap.
5.6.3 Process monitoring (option)
To monitor the rotary vane pump oil pressure during operation, an operating fluid monitoring unit can be
mounted to the side of the stand. The contact in the pressure switch opens when the pressure drops
and when the pump is at a standstill. The signal can be used to control external valves.
Installation
27/66