Adjustment
12 - 42
3
387
Output Ax (motor running) is active
B,C
OFF - ON
ON
ON = with pedal = 1D (motor running)
OFF = with pedal = 1 (lower presser foot)
4
407
Disconnect cable break detection unit of
B,C
OFF - ON
ON
5
522
Needle position when stop occurs,
B,C
OFF - ON
OFF
during decorative backtack
ON = position 2 (raised)
OFF = position 1 (lowered)
523
Backtack
A,B,C
OFF - ON
OFF
ON = decorative backtack (stitch-in-stitch)
OFF = standard backtack
530
Speed (max.) for decorative backtack
B,C
300 - 2000
1000
538
Timing of output Ax
B,C
10 - 90
40
(thread tension release)
(0 = 100% power)
584
Backtack
B,C
OFF - ON
OFF
ON = four times, OFF = double
585
Speed limitation
B,C
300 - 4800
1200
6
605
Actual value on display (<725>)
B,C
OFF - ON
OFF
ON = yes, OFF = no
606
Speed: Level 1 (min.)
B,C
30 - 300
180
607
Speed: Level 12 (max.)
B,C
300 - 6000
1500
608
Speed level curve
B,C
OFF - ON
ON
(pedal characteristic)
ON = linear, OFF = not-linear
609
Trimming speed 1
B,C
60 - 300
180
615
End recognition when light barrier goes
B,C
OFF - ON
OFF
ON = from light to dark
OFF = from dark to light
618
Inverse rotation after seam end
B,C
OFF - ON
OFF
ON = yes, OFF = no
623
Start delay (ms) for inverse rotation
B,C
0 - 2000
30
642
Presser foot – time from switch-on to
B,C
10 - 150
100
voltage reduction (cycle)
Group
Parameter
Setting
range
Set
value
User
lever
Description