Adjustment
12 - 39
12
.07
Parameter settings
12
.07.01
Example of a parameter input
●
Switch on the machine.
●
Press the
TE/Speed
key twice to enter the parameter input function.
The status text "TE" appears on the display and the pedal functions are blocked, to avoid
the machine starting accidentally.
●
Select the desired parameter, e.g. "111" light barrier compensation stitches, by pressing
the corresponding
plus/minus key.
●
With the corresponding
plus/minus key
, set the desired value for the parameter, e.g. "12"
No
No
VAL
A
111
10
TE
VAL
2 x
●
By pressing the
TE/Speed
key the value is taken over and the machine switches to the
sewing mode.
No
VAL
A
111
12
TE
No
VAL
101
OFF