Adjustment
12 - 41
1
101
Audible signal of the control panel key
A,B,C
OFF - ON
OFF
105
Speed for seam start
B,C
300 - 2000
1200
106
Speed for seam start
B,C
OFF - ON
OFF
ON = variable (pedal-controlled) <107>)
OFF = constant (<105>)
107
Speed for seam start with <106> = ON
B,C
OFF - ON
OFF
ON = limited by <105>
OFF = limited by <607>
110
Speed for seam end
B,C
300 - 2000
1200
111
Light barrier compensation stitches
A,B,C
2 - 50
10
stitches from light barrier light to seam
end
112
Number of stitches for light barrier
A,B,C
0 - 100
0
fade-out on knitted fabrics
(according to stitch size)
113
Start with light barrier
B,C
OFF - ON
OFF
ON = only when light barrier is dark
OFF = also when light barrier is light
116
Number of soft start stitches (soft start)
A,B,C
0 - 30
0
117
Speed for soft start stitches
B,C
30 - 640
400
199
Speed for light barrier compensation
B,C
300 - 2000
1200
stitches
3
301
Switch-on voltage of the magnet for
C
OFF - ON
OFF
feed reverse
ON = 24V, OFF = 32V
364
Meaning of feed change-over for
B,C
OFF - ON
ON
ON = backtack, OFF = stitch condensation
382
Switching threshold of the analogue
B,C
0 - 100
15
input for the thread monitor
12
.07.03
List of parameters
Only appropriately trained staff may change the set values in the parameters
of user levels "
B
" and "
C
".
Group
Parameter
Setting
range
Set
value
User
lever
Description