Adjustment
12 - 4
Fig. 12 - 02
1
2
49-017a
16,5 mm
12
.05.02
Preliminary adjustment of the needle height
Requirement
With the needle bar at b.d.c. the distance between bottom edge of the needle bar and the
needle plate must be
16.5 mm.
●
Adjust needle bar
1
(screws
2
) according to the
requirement.