Adjustment
12 - 32
3
1
2
Fig. 12 - 29
12
.05.29
Limiting the stitch length
●
Loosen screw
1
(accessible through the assembly hole) or screw it out according to the
limit to be set.
●
Set the stitch length control lever
2
at the desired maximum stitch length.
●
Set the limiting angle
3
from above so that it touches the control lever
2
and secure it
(in the desired position) by tightening screw
1