![Pfaff 3734-2/01 Instruction Manual Download Page 76](http://html1.mh-extra.com/html/pfaff/3734-2-01/3734-2-01_instruction-manual_1534343076.webp)
Adjustment
12 - 42
7
714
Brake ramp
1 – 50
30
715
Reference position
0 – 191
17
716
Time-out
0 – 255
40
717
Starting current motor
3 – 10
8
718
Antivibration filter
1 – 10
6
719
Rotation direction allocation
0 – 1
0
720
Reference position correction
0 – 191
64
8
801
Right of access function group 100
0 – 1
0
802
Right of access function group 200
0 – 1
1
803
Right of access function group 300
0 – 1
1
804
Right of access function group 400
0 – 1
1
805
Right of access function group 500
0 – 1
1
806
Right of access function group 600
0 – 1
1
807
Right of access function group 700
0 – 1
1
808
Right of access function group 800
0 – 1
1
809
Enter access code
0 – 9999
1493
Group Parameter
Meaning
Setting
Standard value
12
.08
Error messages
Error 1:
System fault
Error 2:
Sewing motor
Error 3:
Area
Error 4:
End of area
Error 5:
Pedal activated at start
Error 7:
Ramp end
Error 11:
Stepping frequency
Error 21:
Power unit overload
Error 22:
Mains voltage
Error 23:
24V too low