Adjustment
12 - 24
12.
05.03
Radial position of the tripping lever
Requirement
With the tripping lever
3
in resting position, there must be a clearance of
0.3 mm
between
its roller and the circumference of the control cam
4.
Fig. 12 - 20
●
Bring the needle bar to BDC.
●
Move solenoid carrier
1
( nuts of screws
2
) in accordance with the
requirement.
4
3
0.3 mm
2
1