Adjustment
37
600
602
Display special inputs
With this function it is possible to
check the special inputs pedal,
reference X (SM1) and reference Y
(SM2). "IN" shows the inputs (PED,
REFX, REFY). Under "VAL" the
respective switch status is displayed.
IN
VAL
PED
Pedal (speed control unit
-1; 0; +1; 2)
REFX
Reference input X
REFY
Reference input Y
603
Connect outputs
With this function the outlets can be
connected. "OUT" shows the outlet
selected (1-16). Under "VAL" the
selected output is set (S) with the
plus/minus key (+), and reset (R) with
the plus/minus key. Interlocks are
checked. Non-assigned outlets are not
connected.
OUT
VAL
1
S/R
Solenoid for
button clamp open
2
S/R
3
S/R
Solenoid for
thread trimming
4
S/R
Solenoid for
thread wiper
5
S/R
6
S/R
Program outlet
7
S/R
Program outlet
8
S/R
9
S/R
10
S/R
11
S/R
12
S/R
13
S/R
14
S/R
15
S/R
16
S/R
604
Move stepping motors
The stepping motors SM1 (X-axis) and
SM2 (Y-axis) are moved individually
with the respective plus/minus keys.
Interlocks are not checked.
Group
Parameter
Description
Setting
Set value
range