Adjustment
34
000
015
Reduced current for stepping motors
ON – OFF
ON
The reduction function of the holding
current at rest with closed button clamp
is switched on or off.
016
Key tone
ON – OFF
ON
The key tone, as reaction to a key on
the control panel being pressed, is
switched on or off. The double tone
for incorrect inputs always remains
switched on.
017
Button clamp solenoid
5 – 100
10
Operating time [10 ms]
The time, for which the solenoid is
under full current, is entered.
018
Button clamp solenoid duty-cycle [%]
5 – 100
20
At the end of the clamp solenoid
operating time (Parameter "017") the
solenoid is clocked. The relationship
between duration of operation and
non-operation is entered here.
019
Thread trimming solenoid
5 – 100
25
operating time [10 ms]
The time, for which the solenoid is
under full current, is entered.
020
Thread trimming solenoid duty-cycle
5 – 100
100
At present without a function
021
Thread take-up lever t.d.c. [°]
45 – 53
51
The position for the t.d.c. thread
take-up lever is entered here. If the
function is executed, the position can
be set by turning the balance wheel.
The access code is necessary for this
adjustment.
022
Thread trimming position
(in relation to t.d.c. needle) [°]
180 - 253
180
The position, at which the thread
trimming solenoid is switched on, is
entered here. The adjustment is set
by turning the balance wheel.
The access code is necessary for this
adjustment.
Group
Parameter
Description
Setting
Set value
range