77
Adjustment
Group
P
arameter
Description
S
et
ting range
S
et value
500
502
Trimming speed (set value x
100
)
5 - 25
2
503
Speed during bobbin winding
2 - 28
15
505
Time for wiper [in 10ms]
1 - 50
30
600
601
Display inputs
With this function the digital inputs can be che-
cked. "IN" shows the input numbers (1 - 16). Under
"VAL" the respective switch status is displayed.
IN VAL
1
SMREF
1
2
SMREF
2
3
IN
1
, programmable input
1
4
IN
1
, programmable input
2
5
Treadle switch
6
-
16
free
602
Display special inputs
IN VAL
PED Pedal (speed control unit –
1
,
0
,+
1
,+
2
)
603
Connect outputs
With this function the outlets can be connected.
"OUT" shows the outlet selected (1-16). Under
"VAL" the selected output is set (S) with the
plus/minus key (+), and reset (R) with the
plus/minus key. Interlocks are checked. Non-assi-
gned outlets are not connected.
OUT VAL
1
S/R
2
S/R
3
S/R clamp
1
closed
4
S/R
Thread wedeler on (optional)
5
S/R
6
S/R clamp
1
open
7
S/R clamp
2
open
8
S/R thread trimming on
9
S/R Thread tension open
10
S/R Secondary thread tension open
(Progr. output
4
)
11
S/R Foot open
12
S/R Thread clamp closed
13
S/R clamp
2
closed
14
S/R
2
nd level jumper foot on
(Progr. output
3
)
15
S/R Progr. output
1
16
S/R Progr. output
2
Summary of Contents for 3108-1/1306
Page 89: ...89 Circuit diagrams Version 10 02 11 91 191 543 95 Part 1...
Page 90: ...90 91 191 543 95 Part 2 Version 15 03 10 Circuit diagrams...
Page 91: ...91 Circuit diagrams Version 15 03 10 91 191 543 95 Part 3...
Page 92: ...92 91 191 543 95 Part 4 Version 10 02 11 Circuit diagrams...
Page 93: ...Note...