31
Setting up
Fig. 9 - 07
9
.07
Adjusting the size of the sewing area
1
●
Finish the parameter input and switch to sewing mode (home position of the machine).
A comparison between the sewing area size entered and the actual sewing area size of the
work clamp ensures that seam programs, which are not within the sewing area size, cannot
be sewn.
If the actual and the entered sewing area size do not concur with each other,
severe damage can be caused to the machine!
●
Measure the sewing area size of work clamp
1
.
●
With the machine in its basic position, select the input mode. (LED is illuminated).
●
Call up parameters "
201
-
204
" in sequence by pressing the relevant
+/- button
.
●
Enter the access code if available - see chapter
11
.
04
.
01
Input access code
.
●
Enter the measured value via the relevant parameter (in
1
/
10
mm
)
NO
VAL
201
-650
X
Y
Parameter
201
=
Min. X-Coordinate (-
650
bis
0
)
202
=
Max. X-Coordinate (
0
bis
650
)
203
=
Min. C-Koordinate (-
1000
bis
0
)
204
=
Max. C-Koordinate (-
1000
bis
0
)
Summary of Contents for 3108-1/1306
Page 89: ...89 Circuit diagrams Version 10 02 11 91 191 543 95 Part 1...
Page 90: ...90 91 191 543 95 Part 2 Version 15 03 10 Circuit diagrams...
Page 91: ...91 Circuit diagrams Version 15 03 10 91 191 543 95 Part 3...
Page 92: ...92 91 191 543 95 Part 4 Version 10 02 11 Circuit diagrams...
Page 93: ...Note...