Regulator/Starter motor relay/Ignition
unit/Starter resistor/HT coil
- Remove the battery access door.
- Disconnect and remove the battery.
- Remove the battery bracket.
- Disconnect and remove the electrical
components.
• The ignition unit, starter relay and lighting
resistance are attached to a removable
holder.
• The regulator and high tension coil are
attached to the chassis.
Checking the starter motor relay
Condition
Operation
Measurement
Standard values
Disconnect and
remove the starter
motor relay.
Between terminals A
R=3.6
Ω
±10%
Between terminals B
R=
∞ Ω
Apply a voltage of 12 V to the A
terminls on the relay.
The relay must trip.
Between terminals B
R=0
Ω
+12V
-
Ω
Ω
A
B