ELECTRICITY
39
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Motocycles
Checking the carburettor heating circuit
- Power supply range of the carburettor
heating resistor: between 10
±2
and 20
±2
°C.
- Remove the luggage carrier (4 screws).
Tightening torque: 25 Nm.
- Remove the plastic cover.
Disconnect the temperature control unit
and take the measurements on the
harness side.
- If the values are correct, replace the
temperature control unit.
- If the values are incorrect, check:
• The harness.
• The ignition switch.
• The carburettor heating resistor.
• Regulator .
• The magneto.
Component
Connector
Wire colours
Standard values
Ground
A
Green
To the ground
R=0
Ω
Resistor warming carburator
A
Yellow/white
To the ground
R=8.5
Ω
±20%
Battery positive power
A
Black
To the ground
Ignition on: U=12V
Ignition off: U=0V
Regulated alternating current
A
Yellow
The engine is running:
U=13.5V
Ω
A
Summary of Contents for Ludix 4T