14 1-800-732-2677
www.petsafe.net 15
Anti-Linger Prevention
The Anti-Linger Prevention feature keeps your dog from staying in the Warning Zone for long periods of time and
draining the Receiver Collar battery. Your dog will hear a warning tone when he reaches the Warning Zone. If your
dog does not return to the Pet Area after two seconds, he will receive a continuous Static Correction until he returns
to the Pet Area.
Run Through Prevention
This system includes a unique “run-through” prevention so that your dog cannot escape the Pet Area without
receiving an increased level of Static Correction. The Receiver Collar automatically increases the Static Correction
when your dog continues more than 20% of the way through the pet fencing Boundary Width. For example, if the
signal is detected 10 feet from the wire and your dog enters the Static Correction Zone, this feature is activated
when he is approximately 8 feet from the Boundary Wire. Your dog will then receive a Static Correction that is
at an increased level corresponding to the Static Correction level setting on the Receiver Collar. The Receiver
Collar is equipped to automatically increase the level of Static Correction the longer your pet remains in the Static
Correction Zone if the collar is set at level 2 or above. The Run Through Prevention sound is an intermittent tone.
Over Correction Protection
In the unlikely event that your pet “freezes” in the Static Correction Zone, this feature limits the static correction
duration to a maximum of 30 seconds. While the system locks out further static correction, the warning tone will
continue until the pet leaves the Static Correction Zone.
Function and Response Table
Indicator Light
Response
Static Correction
Level
Receiver Collar Function
Temperament of Pet
1 Flash
1
No Static Correction, Tone Plus Vibration Initial Training Mode
2 Flashes
2
Low Static Correction
Timid
3 Flashes
3
Medium Static Correction
Timid or Average
4 Flashes
4
Medium High Static Correction
Average or High Energy
5 Flashes
5
High Static Correction
High Energy
Flashes once every
4 to 5 seconds
Indicates Low Battery
Set the Boundary Width and Test the Receiver Collar
With the Boundary Wire in place and properly connected, it is time to set the containment
field and test the system.
The Receiver Collar should NOT be on your dog when the system is tested.
Note: The Receiver Collar is waterproof, which can make the tone hard to hear.
The flashing Test Light when held to the Contact Points indicates the Receiver Collar is
delivering Static Correction. To best utilize the automatic Run-Through Prevention feature,
the containment Boundary Width should extend at least 6 to 10 feet on each side of the
Boundary Wire (total Boundary Width of 12 to 20 feet).
6A
Step
6
Summary of Contents for PIG00-100777
Page 31: ...www petsafe net 31...