PRECAUTIONS

 

All PestWest traps are fully 

insulated, Class I appliances, 

nevertheless, sensible 

precautions should be observed: 
•  Switch off the machine 

before servicing or cleaning

•  Do not install where 

dangerous concentrations of 

flammable gases or dusts are 

likely to occur 

•  Ensure the unit is properly 

earthed 

•  Avoid working on the 

machines whilst they are still 

connected to the mains

•  Ensure that operators have 

an adequate and secure 

working platform, when 

working on the machines

•  Do not allow the glue board 

to become over-filled with 

dead insects. Change at 

regular intervals as required 

by the catch or at least every 

6-8 weeks. Ensure PestWest 

glue boards are fitted as 

replacement

•  The unit is designed for 

indoor use only and is not 

rain-proof  

•  Not suitable for use in barns, 

stables or similar locations

•  Maintenance may be 

carried out by people with 

reduced physical, sensory or 

mental capabilities or lack 

of experience or knowledge 

if they have been given 

supervision or instruction

•  Keep out of reach of children
•  Not for use by children

PRODUCT DESCRIPTION 

All PestWest flytraps are made using the highest 
quality materials. The bodywork is polyester 
powder coated zintec steel (rust-resistant) with a 
polished aluminium reflector (Stainless steel 304 
Grade front cover also available). 

 

The unit retains a PestWest sticky board. 
PestWest units are fitted with Quantum BL tubes 
with FEP shatterproof coating as standard to 
EN61549. 

The Chameleon Sirius offers the latest 
generation of higher energy efficient T5 lamp 
technology. These lamps are powered by a state 
of the art high frequency electronic ballast 
that is more energy efficient than traditional 
magnetic ballasts, and being entirely automatic 
no separate starters are required. Electronic 
ballasts also increase the performance of 
fluorescent lamps.

UNPACKING YOUR UNIT

 

Each unit is carefully inspected and packed 
before leaving our factory.  Before discarding 
the outer carton, examine for obvious evidence 
of transport damage. Remove the unit and pay 
particular attention to the removal of all packing 
materials, before installing the unit. 

MODE OF OPERATION

 

Electrical flytraps operate on the principle 
that most flying insects are attracted to light, 
particularly to the ultraviolet (UV) end of the 
light spectrum. Since insects are still active and 
will fly at night, traps should be left operating 24 
hours a day.

SITING

 

The efficiency of the unit can be affected by 
the intensity of other light sources, e.g. daylight.
Therefore, mount the unit where competition from 
other light sources is minimised.

In food areas, mount close to, but not directly over, 
exposed food or preparation surfaces (preferably 
to attract flies away from sensitive areas rather than 
attract towards them). Observe where the flies tend 
to congregate and if possible, put your flytrap in or 
close to that area.

Site the units near where flies are likely to gain 
access, e.g. doors and windows opening to the 
outside, especially dustbin areas.

Position the trap where it can be easily 
reached around head height; not over working 
machinery where access may be difficult or 
dangerous.

INSTALLATION 

Select the optimum position for the Chameleon 
Sirius using the guidelines given in the ‘SITING’ 
section. 

The PestWest Chameleon Sirius is supplied with 
a 2 metre power cord, terminated in a plug to 
suit local outlets, and operates from a 220-240V 
50-60Hz supply. If it is necessary to extend 
the power cord, a competent electrician must 
do this. Ensure that once installed, the cord is 
adequately secured. 

The unit has 4 keyhole slots on the rear panel 
to permit wall mounting, using the screws 
and masonry plugs provided. The unit can be 
mounted either horizontally, or vertically, in any 
orientation, enabling the power cord to exit the 
unit on whichever side is preferred, to best suit 
the electrical socket location, and provide a neat 
installation.

The unit is supplied, as standard, to be mounted 
with the switch under the main chassis, or 
vertically in either orientation. If these mounting 
options are chosen, there is no need to remove 
and rotate the front cover.

NB: In certain orientations, the cover may 
need to be rotated, to prevent the glue board 
dropping out of the unit. Refer to ‘FRONT COVER 
ROTATION’ for instructions. 

The power cord can then be routed in any 
direction. Only 2 Keyholes should be used for 
horizontal mounting, whilst 4 Keyholes should 
be used in vertical mounting

Mark off the necessary fixings points onto the 
mounting surface using the template provided. 
Drill to a depth of 40mm using a 5.5mm drill bit. 
Place the plastic plugs into the wall then screw 
the screws into the plastic plugs leaving the 
head of the screw approximately 10mm from 
the wall. The unit will now hook over the screws 
because of the keyhole feature. 

NB: If the wall is plasterboard or stud partitioned 
etc, suitable fixings must be used to ensure the 
unit will be secure. 

Once the unit is securely installed, you will need 
to remove the backing paper from the glue 
board to reveal the glue surface. 

FRONT COVER ROTATION (OPTIONAL)

Unscrew the 4 screws which are securing the 
cover to the mount panel using a pozidrive 
screwdriver. Ensure the cover is rotated so that 
the ‘board stop’ feature on the board guides is 
located to whichever face of the unit has been 
selected to be the underside. Failure to do this 
will result in the glue board falling out of the 
unit.

NB: Do not attempt to remove, or tamper with, 
the nuts holding the board guides in place. 
These have been fixed to a set torque and if over 
tightened, may snap off the threaded studs, and 
make the cover unusable.

Chameleon Sirius

INSTRUCTIONS FOR USE AND MAINTENANCE  *  PLEASE SWITCH OFF MACHINE BEFORE SERVICING

Summary of Contents for Chameleon Sirius

Page 1: ...ONS FOR USE INSTRUCTIONS FOR USE GEBRUIKSAANWIJZING INSTRUCCIONES ISTRUZIONI PER L USO BEDIENUNGSANLEITUNG NOTICE D INSTRUCTIONS INSTRUKCJA OBS UGI PestWest Electronics Ltd operates a quality manageme...

Page 2: ...Observe where the flies tend to congregate and if possible put your flytrap in or close to that area Site the units near where flies are likely to gain access e g doors and windows opening to the out...

Page 3: ...h installation Once earthed the Live and Neutral cables can then be reconnected to the connector block as before Ensure all cables are securely fastened by firmly tugging on them None of the cables ru...

Page 4: ...door de paragraaf Plaatsing te raadplegen De Chameleon Sirius wordt geleverd met een wisselstroomkabel van 2 meter lang waarvan n uiteinde eindigt met een stekker die toelaat om deze te verbinden aan...

Page 5: ...geen schuurmiddel of schuursponsje De UV lampbuizen moeten minimaal 1x per jaar worden vervangen Om de efficientie van het toestel te behouden moet deze uitgerust zijn met Quantum BL lampbuizen Dit v...

Page 6: ...atraer a las moscas fuera de zonas sensibles en vez de hacia ellas F jese en donde se congregan las moscas y si es posible coloque el aparato all o lo m s cerca posible Coloque el aparato en una posic...

Page 7: ...elo con un trapo humedecido con agua y detergente o un limpiador de marca No use trapos o limpiadores abrasivos Se recomienda cambiar los tubos fluorescentes de luz ultravioleta por lo menos cada a o...

Page 8: ...e PestWest montano tubi Quantum BL infrangibili con rivestimento FEP come da standard EN61549 La Chameleon Sirius offre la pi recente tecnologia di tubi T5 ad alta efficienza energetica Questi tubi so...

Page 9: ...olta che l unit cablata in modo sicuro si pu allora riassemblarla Il procedimento di montaggio l opposto della procedura di smontaggio PULIZIA E MANUTENZIONE Per mantenere l aspetto piacevole delle un...

Page 10: ...licht m glichst gering ist In Lebensmittelbereichen sollte das Ger t in der N he von aber nicht direkt ber offenen Lebensmitteln und Lebensmittelzubereitungsfl chen platziert werden Die Fliegen sollte...

Page 11: ...t werden REINIGUNG UNDWARTUNG Um das attraktive Erscheinungsbild der Ger te zu erhalten sollten sie so oft wie n tig gereinigt bzw abgewischt werden Verwenden Sie dazu ein angefeuchtetesTuch mit etwas...

Page 12: ...ont susceptibles de p n trer c est dire pr s des portes et fen tres ouvertes sur l ext rieur notamment en cas de pr sence de conteneurs d chets Attention toutefois ne pas attirer les insectes de l ext...

Page 13: ...ermement Aucun des fils lectriques provenant du ballast ou reliant la barrette et l interrupteur ne doivent tre manipul s Lorsque l appareil a t s rement reconnect il peut alors tre r assembl Pour l a...

Page 14: ...t p innych r de wiat a jest minimalny lub ograniczony W pomieszczeniach gdzie jest ywno lampy nale y montowa blisko ale nie bezpo rednio nad odkryt ywno ci najlepiej tak aby odci ga owady od miejsc pr...

Page 15: ...lowania urz dzenie mo na ponownie z o y poprzez wykonanie wy ej opisanej procedury w odwrotnej kolejno ci CZYSZCZENIEIKONSERWACJA Dla osi gni cia atrakcyjnego wygl du lamp nale y je czy ci i my tak cz...

Page 16: ...PestWest 6 8 PestWest PestWest 304 PestWest PestWest EN61549 The Chameleon Sirius 5 24 The Chameleon Sirius PestWest Chameleon Sirius 2 220 240 50 60 3 40 5 5 10 Chameleon Sirius...

Page 17: ...4 4 350 375 PestWest PestWest 6 8 PestWest Chameleon 4 4 EX G PestWest 80 90 135 000047 PestWest Chameleon 130 000177 PestWest 14 21 PestWest 3...

Page 18: ...Chameleon Sirius...

Page 19: ......

Page 20: ...n Fly Control PestWest Electronics Limited West Yorkshire United Kingdom Office 44 0 1924 268500 email info pestwest com www pestwest com Version 01 AUG2016 PestWest Electronics Ltd operates a quality...

Reviews: