2.9 Output Connection
The RCP-GPIO Control Panel provides 32 form "A" relay outputs (Figure
2-8). Each control panel output utilizes one 3-pin Weco connector . Each
3-pin output connector provides; a signal ground connection (pin 3), a
relay wiper connection (pin 2), and a relay normally open connection (pin
1). The maximum voltage rating of the output relay contacts is 100VDC or
100V Peak to Peak AC. The maximum current rating of the output relay
contacts is 1A continuous or 0.5A switched.
12
:
*1'
5HOD\
Figure 2-8 Typical Output
2.10 Power Connections
Power for the RCP-GPIO Control Panel is supplied by an external 7.5
VDC, 800 mA power supply.
Remove the power supply from the box it was shipped in and check to
insure that no damage has occurred in shipping. Verify that the power
supply is rated for the proper AC voltage (i.e. 115 VAC or 230 VAC) be-
fore connection to the AC line voltage. The power connector can now be
plugged into the
POWER IN
connector on the rear of the control panel.
The power supply will immediately power the unit upon connection to the
AC line voltage. See Figure 2-9.