Section 2
page 2.3
10/96
P/N 81905903860
INSTALLATION
2
Installation
RCP-GPIO
2.4 Polling Address
For the system controller to identify a particular control panel, a specific
device number or polling address must be assigned to each panel. Se-
quential binary numbers (1 thorough 1023) are used for this purpose. The
appropriate binary number is entered into the control panel by setting an
internal 10-position DIP switch to the selected binary number. The DIP
switch is located on the Remote CPU Board and is accessible from the
rear of the unit. The panel address is normally assigned and entered at
the factory if the panel is purchased as part of a system and a design
guide has been completed by the user. If the panel is purchased sepa-
rately, the user may be required to set the panel address.
EXAMPLE:
To select polling address 21, set switches 10, 8, and 6 to the
"ON" or "1" position. See Figure 2-2.
Figure 2-2 DIP Switch Setting