Pagina 32 di 53
4 - INSTALLATION
4.8) COUPLING THE CHRONOTHERMOSTAT TO THE RECEIVER
(self-learning)
For this operation, carefully consult the receiver instructions
PRELIMINARY OPERATIONS
•
Install and power the receiver.
•
Program the chronothermostat as indicated in chapter .
5
This function can be protected by a password (see chapter ).
8
ON THE CHRONOTHERMOSTAT
•
Press the
key for 4 seconds; a
message will appear on the display.
Test
tESt
•
The symbol of an antenna will appear on the display, blinking will appear
every 3 seconds (fig.
).
“ ”
C
Test signal transmission will remain active for 3 minutes maximum.
ON THE RECEIVER
•
Perform coupling instructions indicated in the receiver instructions manual.
ON THE CHRONOTHERMOSTAT
(coupling operations output)
•
Press the
key for at least 1 second, then release (e.g. fig.
).
Test
“ ”
D
•
The program previously in progress will appear on the display.
The chronothermostat is coupled to the receiver.
Note: in the event of chronothermostat RESET, coupling with a receiver
will not be cancelled.
press for 4 seconds
press for 1 second
fig. C
fig. D
0
8
10 12 14 16 18 20 22
2
4
6
t1
t2
t3
.
.
.
t1
t2
t3
0
8
10 12 14 16 18 20 22
2
4
6
.
.
.
62
EN
4 - INSTALLATION
4.9) RADIO SIGNAL INTENSITY VERIFICATION TEST
This function can be protected by a password (see chapter ).
8
ON THE CHRONOTHERMOSTAT
•
Press the
key for 7 seconds; a
message will appear on the display.
Test
bEEP
•
The symbol of an antenna will appear on the display, blinking will appear
every 3 seconds (fig.
).
“ ”
E
ON THE RECEIVER
•
At every signal reception, 1, 2 or 3 brief acoustic signals will be emitted, based
on intensity (1= LOW, 2 = MEDIUM, 3 =HIGH) of the received signal.
•
The corresponding LED “
” will blink
•
The
(indicator of signal intensity) will light up briefly at each
3 VMETER LEDs
signal reception, depending on the intensity of the received signal.
Test signal transmission will remain active for 3 minutes maximum.
Deactivating the "radio signal intensity verification test" operation
ON THE CHRONOTHERMOSTAT
•
Press the
key for at least 1 second, then release (e.g. fig.
).
Test
“ ”
F
•
The program previously in progress will appear on the display.
press for 7 seconds
press for 1 second
fig. E
t1
t2
t3
.
.
.
fig. F
t1
t2
t3
0
8
10 12 14 16 18 20 22
2
4
6
.
.
.
0
8
10 12 14 16 18 20 22
2
4
6
For this operation, carefully consult the receiver instructions
63
EN