9.
Position the strap tensioner such that the strap just touches the pipe between the sensor and the strap
tensioner as per images below.
Note:
The relative positions of the strap tensioner and the sensor change depending on the pipe diameter.
On pip
es of less than 4” diameter, position the sensor and
tensioner on opposite sides of the pipe.
Note:
If there are obstructions which do not allow for the recommended strap tensioner position relative
to the sensor, then move the strap tensioner away from the sensor to the closest accessible position.