Re-installing a sensor (if required)
If the sensor is producing a poor-quality ultrasonic signal, it can be reinstalled:
1.
Attach the CC21 to the tablet PC and the sensor and run the installation app.
2.
On the Installation tab, press the Reset button and then follow the instructions described in Task 4.
Note:
The sensor will no longer join the network until the Complete button is pressed again.
3.
If the sensor has to be moved, loosen the strap by undoing the worm-screw in contact with the pipe
until the strap is released from the worm-drive, then follow the instructions described in Task 1 as for
a new installation. Where possible, leave the lanyard in place to prevent a hazard should the sensor fall.
Do not cut the strap while it is under tension. Doing so will
result in the sudden release of energy from the tensioner
which could cause damage or injury.
4.
Before re-installation, ensure the ring and shoe are still in place. If either is missing, do not use the
sensor.
Re-provisioning a sensor (if required)
A sensor can be re-provisioned, if required to assign the sensor to a different gateway, without needing to
physically reinstall the sensor:
1.
Remove the power module and attach the CC21 to the tablet PC and the sensor and run the
installation app.
2.
On the Provision tab, enter the new provisioning information.
3.
Click the Provision button.
The Join Network button can be pressed to start the sensor join process and receive on-screen feedback
about the join state of the sensor.
Note:
Although the join process often takes just a few minutes, it can take several hours depending
on the size and activity of the network.
See
User guide
–
IK220 installation kit
for more details about using the status bar to identify the join state.
Maintenance
The ET310 sensor is a sealed unit with no user serviceable parts.
See
Installation guide - BP series power module
if the power module requires changing.