![Permasense ET310 WiHART Installation Manual Download Page 5](http://html1.mh-extra.com/html/permasense/et310-wihart/et310-wihart_installation-manual_1531129005.webp)
5
Permasense Ltd, Alexandra House, Newton Road, Manor Royal, Crawley, RH10 9TT, UK
www.permasense.com
+44 20 3002 0922
6.
Carefully place the sensor in the required location on the pipe. Note that
the magnets used in the sensors have a high pull force. To avoid damage,
and to get the precise location for each sensor, initially place the sensor at
an angle to the pipe
…
…
and then gently lower the shoe onto the pipe.
Note:
One person should hold the sensor until the strap is installed.
7.
Feed the previously cut strap through the slot
hole of the sensor and around the pipe.
8.
Then feed the free end of the strap into the
other end of the strap tensioner and using the
flathead screwdriver or wrench and socket
provided, turn the screw on the tensioner until
the end of the strap emerges from under the
worm drive (at least 5 turns of the worm-screw
is required).