background image

Page | 10 
 

8.0  12 Month Component Guarantee 

If within the guarantee period of a product any defect is discovered in respect of workmanship, construction or 
material, we will make good the defect or replace the defective part at our expense inside normal working hours at 

the company’s premises providing, written notice is given immediately the defect is disco

vered and that, if required 

by us, the part or complete unit is returned to the company’s premises carriage paid. Spares or repaired parts are 

delivered ex works exclusive of fitting. The guarantee does not apply to defects caused by incorrect installation, 
abnormal conditions of working, accidents, misuse or neglect. Our responsibility is in all cases limited to the cost of 
making 

good the defect or replacing the defective part at the company’s premises inside normal working hours. We 

exclude all liability for any consequential or other damage or losses which may occur. We will not be liable if the 
pumping system fails due to it having been incorrectly specified (e.g. where the pump is inundated due to an 
inadequate waterproofing design or where the pump is used to discharge inappropriate media). 
 

 

 

 

 

 

 

All Permagard products are of a high quality and subject to rigid quality control. The company, however, cannot govern the conditions of usage and application of its products and any warranty, 
written or implied covers material only. The information contained in this leaflet is given in good faith but no liability can be assumed by the Company for any damage, loss, injury or patent infringement 
arising from its use.  

Permagard Products Limited

   

Chittening Industrial Estate, Avonmouth, Bristol. BS11 0YB. 

T: 0117 982 3282  W: www.pemagard.co.uk  E:[email protected]

 

Summary of Contents for PermaSEAL

Page 1: ...Page 1 BASEMENT SUMP AND PUMP SYSTEM Installation and Operation Guidelines...

Page 2: ...Page 2 Contents 1 Product Summary 03 2 Installation Guidelines 03 3 Technical Specification 08 4 Dimensions 08 5 Parts List 08 6 Maintenance 09 7 Health and Safety 09 8 Guarantee 10...

Page 3: ...or to work commencing The tank is manufactured from polyethylene and as such is extremely robust However as with any preformed tank they are susceptible to floatation and hydrostatic pressures exerted...

Page 4: ...e pump s are set up with the waste pipework float arms and alarm outside of the sump chamber to ensure correct fitting For the single pump system please follow this set up 1 Use PTFE tape around the t...

Page 5: ...ion firmly 2 For both the master and the backup mount the float arm onto the waste pipe using the jubilee clip As per fig 1 3 At this point both pumps will activate at the same time as both float arms...

Page 6: ...tion setting levels may need to be finely tuned when the pumps are in the chamber and water levels can be tested Once the pump or pumps are set up the internal waste pipe connections can be made Simpl...

Page 7: ...not exceed 150mm at any time Please ensure that when pouring the concrete backfill suitable steps are taken to prevent the concrete from entering the tank and drainage channel 8 Where groundwater is p...

Page 8: ...Parts List Locked Sealed Lid Frame with 46mm recess One or two CP 250 Pumps 50mm pressure rated pipe work including a shut off valve and non return pump connection Single pump systems have a single i...

Page 9: ...systems must be vaccinated against diseases to which they may be exposed A first aid kit must be close to hand Note that special rules apply to installations in an explosive atmosphere Special note s...

Page 10: ...placing the defective part at the company s premises inside normal working hours We exclude all liability for any consequential or other damage or losses which may occur We will not be liable if the p...

Reviews: