Column Refrigeration Service Manual
94
1. ROTATE THE BIN ALL THE WAY DOWN, SO IT IS RESTING ON
THE BOTTOM OF THE CABINET FULLY OPEN.
2. LOCATE THE END FITTING ON THE GAS SPRING ON THE LEFT
SIDE OF THE BIN AND USING THE FLAT HEAD SCREWDRIVER,
RELEASE THE END FITTING BY PLACING THE FLAT HEAD
SCREWDRIVER INTO THE RELEASE LATCH AND PRYING
OUTWARD TO DISENGAGE THE END FITTING FROM THE
CABINET WALL FITTING.
Removal - Damper Tip-Out Bin
Operation #1
Operation #2
1.
Rotate the bin all the way down, so it is
resting on the bottom of the cabinet fully
open.
2.
Locate the end fitting on the gas spring on
the left side of the bin and using the flat
head screwdriver, release the end fitting
by placing the flat head screwdriver into
the release latch and prying outward to
disengage the end fitting from the cabinet
wall fitting.
1.
Remove all contents from the tip-out bin, including glass
divider and bottom panel.
2.
Open tip-out bin until the right side damper end is showing.
3.
While supporting the tip-out bin, locate the damper end
fitting on the right side. Using a flat head screwdriver,
release the end fitting on the damper, by placing the flat
head screwdriver into the release latch and prying inward to
disengage the end fitting from the bin fitting.