Column Refrigeration Service Manual
108
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
Always wear safety glasses and use other necessary
protective devices or apparel when installing or
working with anchors. Anchors are not recommended
for use in lightweight masonry material such as block
or brick, or for use in new concrete which has not
had sufficient time to cure. The use of core drills is
not recommended to drill holes for anchors.
Before moving unit into position, secure the door
closed and protect any finished flooring.
Use an appliance dolly to move the unit near the
opening.
8.19 Cabinet Anti-Tip/Anti-Tip Bracket
To prevent the unit from tipping forward, the
anti-tip bracket must be installed. Use all anti-tip
bracket hardware as instructed. Level as instructed
on
Page 98 prior to installing anti-tip bracket(s)
The anti-tip bracket and supporting hardware
is included with your unit. Please note that four
anti-tip brackets are required for each unit or dual
installation. In the case of dual installation, each
individual unit must be outfitted with the two anti-
tip brackets on cabinet sides for a total of four.
For drawings of the anti-tip bracket installation
on integrated (built-in) units,
see
. For
drawings of the anti-tip bracket installation on
freestanding units,
see
.
CAUTION
WARNING
WARNING
CAUTION