Model
Temperature
Sensor 1
Temperature
Sensor 2
Temperature
Sensor 3
Temperature
Sensor 4
Temperature
Sensor 5
Temperature
Sensor 6
NTC Thermistor NTC Thermistor NTC Thermistor NTC Thermistor Temp/Humidity
Sensor
Temp/Humidity
Sensor
Refrigerator
Main
Compartment
Deli Drawer
Meat Drawer
Evap Temp
Produce
Drawer
Freezer
Main
Compartment
Evap Temp
Single-Zone
Wine
Evap Temp
Main
Compartment
Dual-Zone
Wine
Evap Temp
Lower
Compartment
Upper
Compartment
Associated
Alarms
P1, L1, H1
P2, L2, H2
P3, L3, H3
P4, L4, H4
P5, L5, H5, R5 P6, L6, H6, R6
**NOTE: Alarm will stop once the cause of the alarm is corrected.
P1, P2, P3, P4, P5, P6 = Open/Disconnected NTC Thermistor or Temperature/Humidity Sensor
L1, L2, L3, L4, L5, L6 = Low Temperature Alarm (Sensed temperature is below X degrees F below setpoint for over 30
minutes)
H1, H2, H3, H4, H5, H6 = High Temperature Alarm (Sensed temperature is above X degrees F above setpoint for over
30 minutes)
r5, r6 = Open/Disconnected Humidity Sensor
d1 = door open alarm
Troubleshooting -
To troubleshoot, check all connections and using a multimeter check resistance values.
Temperature
(°C)
Temperature
(°F)
Resistance
(OHMS)
Temperature
(°C)
Temperature
(°F)
Resistance
(OHMS)
-30
-22
111300
15
59
14690
-25
-13
86430
20
68
12090
-20
-4
67770
25
77
10000
-15
5
53410
30
86
8313
-10
14
24270
35
95
6940
-5
23
33900
40
104
5827
0
32
27280
45
113
4911
5
41
22050
50
122
4160
10
50
17960
55
131
3536
Table 7.3. Column Temperature/Humidity Sensors
Table 7.4. Temperature - Resistance Values
Column Refrigeration Service Manual
71
7.4 Temperature Probes
Below is a table showing the type of probe used for sensing temperatures for each model. The probe is a