Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter
Installation Guide
14
Bank 2
PSE Enable Copper-1 (Switch 1, 2)
PSE Enable Copper-2 (Switch 4, 5) (dual
copper models only)
Switch Position 1, 4
Switch Position 2, 5
Type
Up (default)
Up (default)
PSE enabled
normal detection
Up
Down
PSE enabled
High capacitance
detection
Down
Up
PSE enabled
Legacy device
detection
Down
Down
PSE disabled
These switches must be set in order to enable the power sourcing function and to
indicate the type of device detection required. If the device type is unknown, the
default should be used as per IEEE802.3af/at standards.
Enabled: When enabled, the media converter will perform Power Sourcing
Equipment (PSE) functions as per IEEE802.3af (POE) or 802.3at-2009 (POE+)
standards.
Disabled: When disabled the media converter will not perform PSE functions.
PD Power Reset 1 (Switch 3)
PD Power Reset 2 (Switch 6) (dual copper
models only)
Switch Position
Mode
Up (default)
Disabled
Down
Enabled
Disabled: When disabled, the loss of fiber link has no effect on PSE power to the
PD device.
Enabled: When enabled, if the media converter detects loss of link on any fiber
port it will turn off PSE output power to the PD device connected to copper port 1.
After 2 seconds, the media converter will restore power to the PD and the power
will remain on until one of the fiber links transitions from the link up to link down
state.
Disabled: When disabled the media converter will not perform PSE functions.