background image

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter  

 Installation Guide

  

 

10

 

DIP Switch Settings 

Bank 1 

Auto Negotiation copper (Switch 1) 

Switch Position 

Copper 1  Copper 2 

Up (default) 

Auto 

Auto 

Down 

Off 

Auto 

Note: Auto negotiation should only be turned off, if the copper link 
partner does not support Auto Negotiation and fixed settings are 
required by the copper link partner. 

Auto: When enabled, the media converter will negotiate with its link partner to 
determine the most optimal parameters for this connection. The S-1110P will 
advertise capabilities of 10,100 and 1000 Mbps, full and half duplex as well as 
pause, and remote fault capabilities to the link partner. 

If the copper link partner does not support Auto negotiation, the S-1110P will 
parallel detect to 10 or 100 Mbps and force Half Duplex mode as per IEEE 
specifications. 

Off: When the Auto Negotiation switch is set to the OFF position, the media 
converter will not negotiate the Ethernet parameters with the copper link partner. 
The parameters used by the media converter will be determined by the Duplex 
(switch 4) and Speed (switch 5) DIP switch settings. 

Note: This switch affects the behaviour of copper port 1 only; copper port 2 is 
always set to Auto. 

Link Mode (Switch 2) 

Switch Position 

Mode 

Up (default) 

Standard Mode 

Down 

Smart Link Pass-Through 

Standard Mode: In this mode, link on the fiber and copper sides can be brought up 
and down independently of each other. A loss of link on either the fiber or copper 
port can occur without affecting the other connection.  

Smart Link Pass-Through In this mode, the link state on one connection is 
directly reflected through the media converter to the other connection. If link is lost 
on one of the connections, then the other link will be brought down by the media 
converter. 

If the media converter has 2 copper or 2 fiber connections, then both must go down 
in order to affect the other connection(s). 

Summary of Contents for S-1110DP

Page 1: ...P N 5500317 12 Perle PoE PoE 10 100 1000 Ethernet Media Converters Installation Guide S 1110P S 1110PP S 1110DP S 1110DPP S 1110P XT S 1110PP XT...

Page 2: ...at 2009 standard The fiber connection can be either single mode SM or multimode MM and can operate over different wavelengths and distances depending on the model selected see table below 2 Port Model...

Page 3: ...110DP S1SC10U S 1110DPP S1SC10U SC SM 10 km 6 2 mi 1310 1490 nm S 1110DP S1SC10D S 1110DPP S1SC10D SC SM 10 km 6 2 mi 1490 1310 nm S 1110DP S1SC20U S 1110DPP S1SC20U SC SM 20 km 12 4 mi 1310 1490 nm S...

Page 4: ...1 4 Port Models SFP Model Dual copper PoE Dual SFP Dual copper PoE Dual SFP Connector xx Mode Distance Wavelength TX RX S 1110DP DSFP SFP Note 1 S 1110DPP DSFP SFP Note 1 Note 1 Fiber characteristics...

Page 5: ...ation Guide 5 S 1110P SFP XT SFP Note 1 S 1110PP SFP XT SFP Note 1 Note 1 Fiber characteristics will depend on the SFP fiber module selected Please visit Perle s website for the most up to date Instal...

Page 6: ...ower up the media converter Auto MDIX Jumper Settings Note The factory settings for Auto MDIX will work for most installations but in the rare case that you need to modify the settings the procedure i...

Page 7: ...connected PD device over the Ethernet cable see PSE function on Dip Switch configurations The wire pairs on the cable used for delivering power will depend on the device The following options are ava...

Page 8: ...select a powering option the Power Options Jumper settings must be set Each copper port has a set of Power Option jumpers To access the Powering Options Jumper settings unscrew the six side screws on...

Page 9: ...The DIP switches are accessible through the opening in the side of the enclosure Bank 1 Bank 2 Bank 1 Bank 2 Note All switch changes take effect immediately Switch changes will cycle power to the PD o...

Page 10: ...Negotiation switch is set to the OFF position the media converter will not negotiate the Ethernet parameters with the copper link partner The parameters used by the media converter will be determined...

Page 11: ...e will be passed through to the local copper connection thus notifying the connected device If the media converter has been set to Smart Link Pass Through mode the effect will be the same as FFA since...

Page 12: ...onverter will use this switch setting for copper port 1 speed 100 When Switch 5 is in the Up position the S 1110P will force the speed to 100 Mbps 10 When Switch 5 is in the Down position the media co...

Page 13: ...ber 1 Switch 7 Loopback Fiber 2 Switch 8 Switch Position Mode Up default Disabled Down Enabled Disabled The loopback feature is disabled This is default position for normal operation The switch must b...

Page 14: ...edia converter will perform Power Sourcing Equipment PSE functions as per IEEE802 3af POE or 802 3at 2009 POE standards Disabled When disabled the media converter will not perform PSE functions PD Pow...

Page 15: ...re learn Mac address routing See Redundant Primary for information on link connections Redundant Primary Switch 8 Note This switch is used in conjunction with the Fiber Redundancy feature to determine...

Page 16: ...erter to the other media converter switch fiber device ensuring that the RX and TX are reversed crossed at the opposite end Installing the Simplex Fiber Cable 1 Locate a 1000Base X compliant simplex 1...

Page 17: ...grounding lug not provided One 18 12 AWG wire not provided Cross head screwdriver not provided Note For your safety when installing this equipment always ensure that the chassis ground connection is...

Page 18: ...r adapter to a power source 3 Check that the PWR LED light is lit Extended Temperature models supplied with a Pluggable Terminal Block 1 Unplug the terminal block from the Media Converter 2 Ensure the...

Page 19: ...loopback mode Blinking fast Power On failure See LED Pattern to determine pattern combination and failure cause LED Pattern FDF LKF FDC PSE Off Off On On SFP incompatible All other LED patterns Inter...

Page 20: ...nk up and receiving data PSE 1 2 Solid Green Active The PSE has successfully detected a compliant PD and is applying power over the UTP Solid Orange Inactive The PSE is not active The PSE has been con...

Page 21: ...automatically configures the connection Pause IEEE 802 3xy Integrated Pause signalling is an IEEE feature that temporarily suspends data transmission between two devices in the event that one of the...

Page 22: ...LED light indicates good copper connection If the LKC LED is not lit the check the copper cable and the attached device 3 Repeat for the far end media converter 4 Connect the fiber cable to both media...

Page 23: ...Guide 23 3 If the PD does not support Alternative A including legacy PD s the Power Option Jumpers must be set accordingly Also ensure the correct pin out for the device 4 For proper detection of diff...

Page 24: ...de Up to 3 048 m 10 000 ft Dimensions 150 mm by 95 mm by 26 mm MTBF 1 copper port No Power supply POE POE 2 SFP 1 copper port 399 432 hours 218 384 hours 79 977 hours 1 SFP 1 copper port 410 188 hours...

Page 25: ...S 1110P S1SC20D S 1110PP S1SC20D SM TX 1490 RX 1390 Min 8 Max 3 Min 22 Max 3 14 S 1110P S2xx40 S 1110PP S2xx40 SM TX 1310 RX 1310 Min 3 Max 5 Min 23 Max 3 20 S 1110P S1SC40U S 1110PP S1SC40U SM TX 131...

Page 26: ...1310 RX 1310 Min 9 5 Max 3 Min 20 Max 3 10 5 S 1110DP S1SC10U S 1110DPP S1SC10U SM TX 1310 RX 1490 Min 9 Max 3 Min 20 Max 3 11 S 1110DP S1SC10D S 1110DPP S1SC10D SM TX 1490 RX 1310 Min 9 Max 3 Min 20...

Page 27: ...S 1110DP S2xx120 S 1110DPP S2xx120 SM TX 1550 RX 1550 Min 0 Max 5 Min 32 Max 9 32 S 1110DP S1SC120U S 1110DPP S1SC120U SM TX 1590 RX 1510 Min 3 Max 2 Min 34 Max 9 31 S 1110DP S1SC120D S 1110DPP S1SC1...

Page 28: ...oduct meets Class I Laser safety requirements per IEC 60825 1 2007 standard and complies with FDA CDRH 21 CFR1040 10 and 21CFR1040 11 WARNING Visible and invisible laser radiation may be present when...