18
Perle IRG5410/5410+Series Router Hardware Installation Guide
IRG5410 Deployment Modes
IRG5410 Deployment Modes
Fixed Installation without I/O
For fixed installations, connect the wires as shown in the figure below. You can configure Low Volt
-
age Standby Mode (LVS) to force the IRG5410 into Standby mode when the voltage is low. Voltage is
monitored on Pin 3 and 4.
• Pin 1 (Power)—Use the Red wire in the DC cable to connect Pin 1 to the power source.
Include a 4.0A fast acting fuse to the input line. A continuous (unswitched) DC power source
is recommended.
• Pin 2 (Ground)—Use the Black wire in the DC cable to connect Pin 2 to Ground.
• Pin 3 (IGN - Ignition)—Connect to Power for voltage sensing.
Recommended Vehicle Installation (Ignition Mode)
For vehicle installations, connect the white IGN wire to the vehicle’s ignition switch as shown in the
diagram below. This allows the IRG5410 to operate with the vehicle. When the vehicle’s ignition is
off the IRG5410 can enter standby mode. You can configure a time delay between the vehicle’s igni
-
tion shuts off, and the time the IRG5410 should go into standby mode. A delayed standby is useful if
you want to maintain a network connection while the vehicle’s engine is shut off for short periods of
time, such as in a delivery vehicle.
• Pin 1 (Power)—Use the Red wire in the DC cable to connect Pin 1 to the power source.
Include a 4.0 fast acting fuse in the input power line. continuous (unswitched) DC power
source is recommended.
• Pin 2 (Ground)—Use the Black wire in the DC cable to connect Pin 2 to Ground.
• Pin 3 (IGN - Ignition)—It is recommended to use the IGN wire (Pin 3) to initiate standby
mode on the IRG5410.