Power Modes
The IRG5410 has three operating power modes:
• Standard Mode
• Ignition Mode
• Smart Standby Mode
Standard Mode
When power is applied to the router, it will power up. All inputs are ignored (from a power up per
-
spective). This is the default.
Ignition Mode
• Configurable time delay for shutdown / start based on vehicle status
This mode monitors the ignition input and goes in and out of Standby mode based on the voltage of
the ignition input. When the voltage on the ignition input goes below a set pre-defined threshold, the
router will be powered down into Standby mode. When the voltage on the ignition input goes above
the Router’s pre-defined value it will return to normal operating mode (Wakeup).
Smart Standby Mode
You can configure a combination of one or two user defined conditions to determine when the router
is powered up and when it goes into Standby mode.