Illustration 85
g06621529
(1) Clamp torque 7 N·m (62 lb in)
Clamps and V-Band Clamp Torques
Table 13
Clamps and V-band Clamp Torques
Clamp
Torque
1
7 N·m (62 lb in)
2
9 N·m (79 lb in)
i08383226
Jacket
Water
Heater
-
Check
(If
Equipped)
Jacket
water
heaters
help
to
improve
starting
in
ambient
temperatures
that
are
below
21
°C
(70
°F).
All
installations
that
require
automatic
starting
should
have
jacket
water
heaters.
Check the operation of the jacket water heater.
Check the operation of the circulation pump, if
equipped. For an ambient temperature of 0 °C
(32 °F), the heater should maintain the jacket water
coolant temperature at approximately 32 °C (90 °F).
i06530584
Overhaul
(Major)
Scheduling
a
Major
Overhaul
The
need
for
a
major
overhaul
is
determined
by
several
factors:
• An increase of oil consumption
• An increase of crankcase blowby
• A decrease and variation of cylinder compression
M0122761
89