PERFECT FRY COMPANY PFC570-HB Installation & Operation Manual Download Page 30

30

TROUBLESHOOTING 

System Error Conditions (continued)



SYSTEM ERROR



PLEASE CHECK

AIRFLOW/AIR FILTER

• 

There is improper air flow

 

• 

Make sure air intake (front) and exhaust 

(rear) vents are not obstructed

• 

Clean grease filter thoroughly

• 

Replace the air filter cartridge

HEATING   PRESET 

     

84

°F

SEE THIS LCD

CAUSED BY

        DO THIS

GET THIS LCD



SYSTEM ERROR



PLEASE CHECK

FIRE EXTINGUISHER

• 

Loss of pressure in the Fire Extinguisher, 

system needs to be recharged

• 

Call PERFECT FRY at (603)225-6684 for 

recommended Fire Service Company near 
you.

HEATING   PRESET 

     

84

°F



SYSTEM ERROR



PLEASE CHECK

PRIMARY OVERTEMP

• 

Heating Element is not installed properly.

• 

Check to see that heater module has been 

properly placed on oil vat

• 

Check to see the electrical connection 

between heater module and connector is 

made at inside back of fryer compartment

• 

Clean the male and female terminals

 on 

connector with rubbing alcohol and 

cotton swab.

HEATING   PRESET 

     

84

°F



SYSTEM ERROR



PLEASE CHECK

SECONDARY OVERTEMP

• 

Cooking too low.

• 

Make sure oil level is between the hot and 

cold lines at rear of vat.

• 

Cooking oil has overheated.

• 

Press 

 and 

 keys together and release 

to reset.

• 

Is it possible the heater module was 

submerged in water?  If so, call  

603-225-6684.

HEATING   PRESET 

     

84

°F



SYSTEM ERROR



PLEASE CHECK

MAIN FAN

• 

Main ventilation fan is not functioning 

properly.

• 

Check main ventilation fan to see if it is 

moving air and the fan blades are moving

• 

Remove obstruction and/or check electrical 

connection 

HEATING   PRESET 

     

84

°F



SYSTEM ERROR



PLEASE CHECK

CONTROL FAN

• 

Control fan is not functioning properly.

• 

Check main ventilation fan to see if it is 

moving air and the fan blades are moving

• 

Remove obstruction and/or check electrical 

connection 

HEATING   PRESET 

     

84

°F

Summary of Contents for PFC570-HB

Page 1: ...mation and retain this manual for the life of the equipment Model ______________________________________ Serial ______________________________________ Date Purchased ________________________________ I...

Page 2: ...are not attributable to a defect in materials or workmanship are not covered This warranty specifically excludes parts which wear or would be replaced under normal usage including but not limited to...

Page 3: ...shipment Take comfort in knowing that our local Authorized Service network is committed to supply ing your service and warranty needs Each Authorized Service and Parts Provider ASAP has dedicated serv...

Page 4: ...turn the Perfect Fry PFC for recycling when it reaches end of life SAFETY FIRST LIFTING MOVING Your Perfect Fry PFC s gross shipping weight is 100 lb 45 kg Net weight 80 lb 36 kg DEEP FRYING Cooking o...

Page 5: ...ms UL 197 UL 197 SB supplement also reference the following standards which your PERFECT FRYER meets applicable parts thereof UL 1046 Grease Filters for Exhaust Ducts UL 300 Fire Testing of Fire Extin...

Page 6: ...ly Air Filter Switch 3HT724 C 8 Assembly Grease Filter 3HT727 NS Switch Grease Filter Door 6HT566 9 Assembly Grease Filter Tray 6ST728 C NS Assembly Filter Drain Hose B6698901 C 10 Assembly Elec Box M...

Page 7: ...ptacle have an electrician install the appropriate NEMA receptacle within 4 feet of the fryer See the manufacturer s label on your Perfect Fry PFC for the electrical Model No PFC570 then check off you...

Page 8: ...23 58 42 Prepare Counter top Area Required Clearances 1 on sides 2 on rear 0 on top Unpack 1 Cut straps on shipping box 2 Remove box top and sleeve 3 Remove outer plastic wrapping and keep box along w...

Page 9: ...ly with additional help as needed and place it in its final location EQUIPMENT SET UP AND CLOSE PROCEDURES INSTALLATION Continued Unpack 1 Air Filter Cage 2 Air Filtration Odor Filter 3 Air Filtration...

Page 10: ...Continued Unpack BLOW OFF CAPS 12 REAR PLUG COVER HOLDER 7 Ensure that blow off caps on fire extinguisher nozzles are kept in place 8 When removing item 12 please relocate to upper holding location de...

Page 11: ...LEASE CHECK CHANGE HEATER BOX GREASE FILTER AIR FILTER REPLACEMENT FRONT PANEL The heater box must NOT be immersed in water or any other liquid 3 Install grease filter into grease filter tray 4 Instal...

Page 12: ...tom cooking compartment Note Indents on bottom of spill tray should fit into matching indents on bottom of cabinet 8 Set heater module onto oil vat Note grooves on bottom of heater module should fit o...

Page 13: ...and inside edge of spill tray Note If drip tray does not fit press heater module in further to complete connection 12 Install basket lift a Hold basket tray vertical b Install rod into pivot hole left...

Page 14: ...trate Cleaner solution APSC Rinse them under hot fresh water then sanitize in sanitizer solution for 1 minute Allow to air dry 3 Open the fryer door and clean the inside of the fryer area by spraying...

Page 15: ...n water and allow to air dry 6 Remove the air filter cartridge and set aside CAUTION Do not wash the air filter cartridges 7 Remove the grease baffle tray from the cabinet Remove the grease baffle fro...

Page 16: ...r solution for 1 minute Allow to air dry NOTE Place the Yellow Protective Cover that comes with the fryer unit back on top of the female connector at the interior back of the unit behind the vat befor...

Page 17: ...ent 3 Remove old used air filter cartridges from air filter cage 4 Wipe air filter cage clean 5 Fit air filter cage over new air filter cartridges as shown and write date on cartridge Arrows up 6 Inst...

Page 18: ...by 10 second increments Number Keys 0 to 9 Preset Key Choose any of the default presets On Off Key To turn ON To turn OFF To put in STANDBY Preset Mode Shows which preset mode the Perfect Fry PFC is...

Page 19: ...ached unit is READY to start cooking READY PRESET 359 F Preset Times Cooking Time Names Factory Defaults Preset Name Time Preset Name Time Preset Name Time 1 HASHBROWNS 3 00 4 AVAILABLE 0 00 7 AVAILAB...

Page 20: ...Wait for Beep 8 Open door 9 Remove Basket 10 Follow steps 2 through 6 to cook another order this way 7 COOKING cycle is complete 8 Basket raised out of oil 9 Basket drains 10 Fryer beeps to inform you...

Page 21: ...D CONTROL Operation Instructions continued Open Door Paused Cooking Safety and Health regulations require doors and panels to be closed during cooking YOU DO THIS 1 Open door during cook cycle Perfect...

Page 22: ...stop 9 LCD goes blank 10 Your Perfect Fry PFC is off DO NOT UNPLUG FRYER Fans must remain ON during COOLDOWN mode Drain Mode Note Oil in Perfect Fry PFC must be cooler than 139 F or drain mode will no...

Page 23: ...UNTERS MORE START TO SELECT Preset Key Use in combination with START CANCEL to access background menu Left Arrow Key Moves menu selection up Toggles character selection up in making preset names Numbe...

Page 24: ...when a basket of product is placed into the fryer CTSTM increases cooking time to accommodate for differences in product moisture content basket load size and initial temperature A proper CTSTM setti...

Page 25: ...a key is pressed Choose between 0 and 9 Default is 4 Units Temperature of oil in the vat Choose between C Celsius and F Fahrenheit Drain Time Time a basket of cooked food sits out of the oil before y...

Page 26: ...BROWNS 2 AVAILABLE 3 AVAILABLE 4 AVAILABLE 5 AVAILABLE 6 AVAILABLE 7 AVAILABLE 8 AVAILABLE 9 AVAILABLE Preset properties that can be changed TIME Cook Cycle Time TEMP Cook Cycle Temperature CTS Cook T...

Page 27: ...onnel FANS Use the arrow keys to turn fans on and off note oil temperature must be below 122 F 50 C Monitor rpm and current values of each fan INTERLOCKS To view interlocks and if they re open or clos...

Page 28: ...ms can be customized by following this basic proce dure some use the arrow keys Option Changes Adding Presets 1 From main menu scroll down to PRESETS using key 2 Press SEE THIS LCD DO THIS GET THIS LC...

Page 29: ...heck to see that front panel is closed securely with two black latches SEE THIS LCD CAUSED BY DO THIS GET THIS LCD HEATING PRESET 84 F SYSTEM ERROR PLEASE CHECK FILTER PLACEMENT Air filter cartridge i...

Page 30: ...le and connector is made at inside back of fryer compartment Clean the male and female terminals on connector with rubbing alcohol and cotton swab HEATING PRESET 84 F SYSTEM ERROR PLEASE CHECK SECONDA...

Page 31: ...heater module Replace electronics box module Baskets will not lower into or rise out of cooking oil Basket lift not working Motor not working Make sure that the basket lift is installed properly Chec...

Page 32: ...ieved by system operation If the pressure in the cylinder drops below 92 psi 6 3 bar the pressure switch opens deactivating the power relay causing the appliance to de energize INSPECTION MAINTENANCE...

Page 33: ...he affected parts must be replaced or repaired 4 The maintenance report with recommendations if any shall be filed with the owner or with the designated party responsible for the PFS 5 The PFS must ha...

Page 34: ...34 THIS PAGE WAS LEFT BLANK INTENTIONALLY...

Page 35: ...r Female Motor Basket PFC Switch Air Filter Switch Airflow Switch Grease Filter L1 L2 G H2 H1 OT NC NC NC NO NC NC C NO NC 1 2 3 4 5 6 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 20 19...

Page 36: ...d NH 03302 0501 Physical Address 553 Route 3A Bow NH 03304 Tel 603 225 6684 Fax 603 225 8472 General Information profits perfectfry com Customer Support service perfectfry com Web www perfectfry com 2...

Reviews: