30
TROUBLESHOOTING
System Error Conditions (continued)
SYSTEM ERROR
PLEASE CHECK
AIRFLOW/AIR FILTER
•
There is improper air flow
•
Make sure air intake (front) and exhaust
(rear) vents are not obstructed
•
Clean grease filter thoroughly
•
Replace the air filter cartridge
HEATING PRESET
84
°F
SEE THIS LCD
CAUSED BY
DO THIS
GET THIS LCD
SYSTEM ERROR
PLEASE CHECK
FIRE EXTINGUISHER
•
Loss of pressure in the Fire Extinguisher,
system needs to be recharged
•
Call PERFECT FRY at (603)225-6684 for
recommended Fire Service Company near
you.
HEATING PRESET
84
°F
SYSTEM ERROR
PLEASE CHECK
PRIMARY OVERTEMP
•
Heating Element is not installed properly.
•
Check to see that heater module has been
properly placed on oil vat
•
Check to see the electrical connection
between heater module and connector is
made at inside back of fryer compartment
•
Clean the male and female terminals
on
connector with rubbing alcohol and
cotton swab.
HEATING PRESET
84
°F
SYSTEM ERROR
PLEASE CHECK
SECONDARY OVERTEMP
•
Cooking too low.
•
Make sure oil level is between the hot and
cold lines at rear of vat.
•
Cooking oil has overheated.
•
Press
and
keys together and release
to reset.
•
Is it possible the heater module was
submerged in water? If so, call
603-225-6684.
HEATING PRESET
84
°F
SYSTEM ERROR
PLEASE CHECK
MAIN FAN
•
Main ventilation fan is not functioning
properly.
•
Check main ventilation fan to see if it is
moving air and the fan blades are moving
•
Remove obstruction and/or check electrical
connection
HEATING PRESET
84
°F
SYSTEM ERROR
PLEASE CHECK
CONTROL FAN
•
Control fan is not functioning properly.
•
Check main ventilation fan to see if it is
moving air and the fan blades are moving
•
Remove obstruction and/or check electrical
connection
HEATING PRESET
84
°F