17
EQUIPMENT SET-UP AND CLOSE PROCEDURES
CLEANING (continued)
Cleaning - Periodic Maintenance
Air Filter Cartridge Replacement
• Re
place the air filter cartridge at least once every 3 months,
more often for higher volume usage. Replacement is safer
and easier when the fryer is cool rather than hot.
•
Only Perfect Fry filters may be used in your Perfect Fry
PFC.
S
teps to replace air filter cartridge
:
1.
Open front panel by turning latches.
2.
Release latch on air filter cage, and remove air filter
cage and air filter cartridges from filter compartment.
3.
Remove old used air filter cartridges from air filter cage.
4.
Wipe air filter cage clean
5.
Fit air filter cage over new air filter cartridges (as
shown) and write date on cartridge (
Arrows up).
6.
Install air filter cage and new air filter cartridge firmly
back into filter compartment and latch in place.
7. Close front panel and latch shut.
A
A
PFS Automatic Extinguisher
• The PFS automatic extinguisher must be inspected
monthly by the owner/operator and semi-annually by
authorized service personnel as per NFPA 17A. It
is important that a maintenance program is set up
with a local fire service company to ensure that local
jurisdictional codes are being met. Please refer to
PFS automatic extinguisher manual (L20-361) for more
information.