background image

WHD-16 Full Height

 

Security Gate 

Dear customers! 

We thank You for choosing the security gate manufactured by PERCo.  

You have purchased a high quality product, which will be long lasting  

in operation provided that installation and operation rules are observed. 

The Installation and Operation Manual (hereinafter 

– the Manual) contains the instructions 

you need for safety transportation, storage, installation, operation, and maintenance of the 

WHD-16

 

full height security gate 

(hereinafter 

– the gate).  

The product installation should be carried out with strict accordance to this Manual. 

Abbreviations: 

PS 

– power supply, 

ACS 

— access control system. 

 
 
 
 

1  APLICATION 

The 

WHD-16

 

full height security gate 

is designed  for management of pedestrian flows 

and  access  control  at  entrance  points  of  facilities  and  areas  with  high  security 
requirements and necessity for full vertical closure of the passageway. 

It  is  advisable  to  determine  the  number  of  the  gates  sufficient  for  fast  and  convenient 
pedestrian  passage  through  the  entrance  point  on  basis  of  the  gate  throughput  capacity 
(sect. 3 of the Manual). 

 

 

 

2  OPERATION CONDITIONS 

The  gate,  in  accordance  with  the  resistance  to  environmental  exposure,  complies  with 
GOST 15150-69, category N2 (outdoor operation). 

Operation of the gate is allowed at ambient temperature from 

–30°C to +40°C and relative 

air humidity of up to 98% at +25°C. 

Summary of Contents for WHD-16

Page 1: ...INSTALLATION AND OPERATION MANUAL WHD 16 Full Height Security Gate...

Page 2: ...Full Height Security Gate WHD 16 Installation and Operation Manual...

Page 3: ...atures 8 5 2 Design and operation 8 6 MARKING AND PACKAGING 9 7 SAFETY REQUIREMENTS 9 7 1 Installation safety requirements 9 7 2 Operation safety requirements 9 8 INSTALLATION 10 8 1 General recommend...

Page 4: ...Abbreviations PS power supply ACS access control system 1 APLICATION The WHD 16 full height security gate is designed for management of pedestrian flows and access control at entrance points of facil...

Page 5: ...urrent 3 A Power consumption 36 W Throughput rate in the single passage mode 12 persons min Average daily throughput in the single passage mode 2 000 persons day Passageway dimensions H W 960 2000 mm...

Page 6: ...on request Power supply 1 MB 16 full height railing sections determined by the customer Fasteners 1 determined by the customer Anchor bolt SORMAT PFG IR 10 15 Finland 2 4 Note Technical characteristic...

Page 7: ...Installation and Operation Manual 6 Figure 1 General view of the WHD 16 gate 1 frame 2 leaf 3 electromechanical lock 4 door closer...

Page 8: ...WHD 16 Full Height Security Gate 7 Figure 2 Overall dimensions of the WHD 16 gate...

Page 9: ...through four mounting holes in the post flanges In the home position closed for entrance and exit the leaf provides complete closure of the passageway between the posts the lock is locked up After th...

Page 10: ...ed for installation Observe general electrical safety rules when laying out the cables Before the turnstile first power on make sure its installation and connection have been made accordingly Power su...

Page 11: ...00 mm for soft grounds using relevant mounting hardware for installation on different foundations making sure the mounting foundation is horizontal and flat the flatness deviation must not exceed 1 5...

Page 12: ...ble to the door sensor Fig 3 Figure 3 Mounting hole pattern 3 Insert sleeves for anchor bolts into the holes so that they do not stick out above the floor surface Attention Be extra cautious and caref...

Page 13: ...mended to install a door sensor reed switch The magnetic part of the sensor is installed in the leaf it is recommended the upper part of the leaf and the sensor itself is installed in the gate frame 8...

Page 14: ...opened with a key or remotely from the inside the lock is opened by pressing the button and remotely with the blocked exit button opening from the outside as in the normal mode and from the inside th...

Page 15: ...s high The gate should be stored indoors at ambient temperature from 40 C to 45 C and relative air humidity below 98 at 25 C The environment should be free of acid and alkali vapours or corroding gase...

Page 16: ......

Page 17: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 18: ...www perco com...

Reviews: