IR-03.1 Proximity Reader
1 GENERAL INFORMATION
Proximity reader
IR-03.1
(hereinafter – the
reader
) is designed for reading and decoding
the code logged into the proximity identifier and its transfer to the controller of PERCo
system operating device.
Colour of the reader housing is marked by the end letter:
IR-03.1B
– light beige;
IR-03.1D
– dark grey.
The reader with regard to resistance to environmental exposure complies with
GOST 15150-69, category NF1 (outdoor operation).
Operation of the reader is allowed at ambient air temperature from -40°C to +40°C and at
relative air humidity of up to 93% at +40°C.
Storage of the reader is allowed in dry indoor facilities at the ambient air temperature from
-40°C to +45°C and at relative air humidity 98% at +25°C.
The reader in the original package should be transported in closed freight containers or
other closed type cargo transport units.
After the transportation or storage at temperatures below zero or at high air humidity the
reader must be kept unpacked for not less than 24 hours indoors within normal climate
conditions prior to putting it in operation.
Marking of the reader is made in form of a label located on the rear panel of the reader
housing. The label contains the following reader data: trademark and manufacturer’s
contact details; model name and number; serial number; year and month of manufacture;
input voltage; power consumption.
Reader is packed in a carton package preventing its damage during transportation and
storage.
Due to continuous improvement of products the Manufacturer reserves the right to modify,
without notice, the product design not aggravating its technical specifications.
2 TECHNICAL SPECIFICATIONS
Rated operating voltage
1
................................................................................... 12±1.2 VDC
Consumption current ..........................................................................................max. 80 mA
Power consumption .................................................................................................max.1 W
Card reading distance at the rated operating voltage for different card (trinket) types:
HID
cards ...................................................................................................... min. 7 cm
EM-Marin
cards ............................................................................................. min. 9 cm
Trinkets ....................................................................................................... min. 4 cm
Card reading distance at reader mounting on metal base-plate:
HID
cards ...................................................................................................... min. 5 cm
EM-Marin
cards ............................................................................................. min. 7 cm
Trinkets ....................................................................................................... min. 4 cm
Controller connection interface .................................................................................
RS-485
1
As a power supply it is recommended to use dc source with linear voltage stabilization and
output pulsation amplitude max. 50 mV.