AS-i 3.0 EtherNet/IP+Modbus TCP Gateway
The Modbus Address Table
26
.9.20
1
3
69
Config_OK!: Configuration error
0:
error
1:
no error
LDS.0: An AS-i slave with address zero is existing
Auto_Address_Assign: Automatic programming is allowed
Auto_Address_Available!: Automatic programming is possible
0: Auto-address is not possible
1: Auto-address is possible
Configuration_Active: The configuration-mode is active
Normal_Operation_Active!: The normal operation mode is active
0: normal operation is not active
1: normal operation is active
APF/not APO: An AS-i power fail occured
Offline_Ready: The off-line phase is active
Periphery_OK!: Periphery is OK
0: Periphery is not OK
1: Periphery is OK
Earth Fault: AS-i earth fault detection
0: no earth fault
1: earth fault
Overvoltage: AS-i overvoltage detection
0: no overvoltage
1: overvoltage fault
Noise: AS-i noise detection
0: no noise
1: noise fault
Duplicate Address: AS-i duplicate address detection
0: no duplicate address
1: duplicate address
4x reference 4226
Bit value
Host Interface-Flags
1
Data_Exchange_Active!
2
Off_Line
4
Auto_Address_Enable!
Tab. 11-44.
Data_Exchange_Active!: If this output is set, no data transmisson between the
AS-i/Gateway and the AS-i slaves is possible.
0: Data exchange is not active
1: Data exchange is active