Table 3.2:
Light grid technical data
Number of beams, beam gap, weight:
Table 3.3:
Number of beams, beam gap, weight
3.9 Electrical connection
SLP emitter and SLP receiver
Depending on the number of beams, T2, T3, T4 and R2, R3, R4 cannot be assigned and
are accordingly labeled "N/C".
Receivers with option L are ready for attaching signal lamps (See Chapter 5). Up to three
signal lamps can be controlled via terminals L1, L2, and L3.
Figure 3.4:
Electrical connection of SLP emitter and SLP receiver
Degree of protection
IP65
Connection
M16 cable gland, terminal compartment
Material
Housing
Extruded aluminum profile, RAL 1021 (yellow) coated
Lens
Plastic lens
Weight
Type
SLP8-2-...
SLP...-2-...
SLP...-3-...
SLP...-4-
Number of beams
1
2
3
4
Beam gap
500 mm
500 mm
400 mm
300 mm
Weight
2100 g
2100 g
3200 g
3500 g
Emitter SLP
Receiver SLP (-L)
Control Unit Saf
eBo
x module 4X
only with option -L
(indicator lamp)
emitter x output
emitter x+1 output
emitter x+2 output
emitter x+3 output
emitter 0 V
receiver x+1 input
receiver x input
receiver x+2 input
receiver x+3 input
receiver 24 V
receiver 0 V
0 V Muting lamp
Muting lamp trigger
R1R2 R3 R4 +U
L- L1 NC NC NC
T1 T2 T3 T4 NC
T1
T2
T3
T4
R2
R3
R4
+U
R1
L-
L1
SB4
-4M