Pulscon LTC
Function group "linearisation" (04)
D
O
C
T
-0
0
9
4
A
0
6
/2
009
12
07
82
35
semi-automatic
The tank is filled in stages when the linearisation c
u
rve is entered semi-a
u
tomatically.
The P
u
lscon LTC a
u
tomatically detects the level and the corresponding vol
u
me/weight
has to
b
e entered. The proced
u
re is similar to man
u
al ta
b
le entry, where the level val
u
e
for each ta
b
le point is given a
u
tomatically
b
y the instr
u
ment.
!
Note!
If the tank is emptied, pay attention to the following points:
•
The n
u
m
b
er of points m
u
st
b
e known in advance.
•
The first ta
b
le n
u
m
b
er = (32 - n
u
m
b
er of points).
•
Entries in
"Tab. no."
(043)
are made in reverse order (last entry = 1).
table on
An entered linearisation ta
b
le only
b
ecomes effective when activated.
clear table
Before making entries into the linearisation ta
b
le, any existing ta
b
les m
u
st
b
e deleted.
The linearisation mode a
u
tomatically switches to linear.
!
Note!
A linearisation ta
b
le can
b
e deactivated
b
y selecting
"linear"
or
"horizontal cyl"
(or the
"level/ullage" (040)
f
u
nction =
"level DU"
,
"ullage DU"
). It is not deleted and can
b
e
reactivated at any time
b
y selecting
"table on"
.