Power Supply PS1000-A6-24.5
Application Notes
20
21
-1
1
37
25.4
Parallel Use to Increase Output Power
Devises can be paralleled to increase the output power. The output voltage shall be adjusted
to the same value (±100mV) with the same load conditions on all devices, or the devices can
be left with the factory settings.
The ambient temperature is not allowed to 40°C.
If more than three devices are connected in parallel, a fuse or circuit breaker with a rating
of 10A is required on each output. Alternatively, a diode or redundancy module can also be
utilized.
Energize all devices at the same time. It also might be necessary to cycle the input power
(turn-off for at least five seconds), if the output was in overload or short circuits and the
required output current is higher than the current of one unit.
Restrictions
•
Keep an installation clearance of 15mm (left / right) between two devices and avoid
installing devices on top of each other.
•
Do not use devices in parallel in mounting orientations other than the standard mounting
orientation or in any other condition where a reduction of the output current is required
(e.g. altitude).
Pay attention that leakage current, EMI, inrush current will increase when using multiple
devices.
Figure 25.5 Parallel use to increase output power
Unit A
Unit B
-
+
-
+
Load
+
-
Input
Output
Input
Output