Power Supply PS1000-A6-24.5
EMC
20
21
-1
1
25
17
EMC
The EMC behavior of the device is designed for applications in industrial environment as well
as in residential, commercial and light industry environments.
The device is investigated according to EN 61000-6-1, EN 61000-6-2, EN 61000-6-3
and EN 61000-6-4.
EMC Immunity
Electrostatic discharge
EN 61000-4-2
Contact discharge
Air discharge
8kV
15kV
Criterion A
Criterion A
Electromagnetic RF field
EN 61000-4-3
80MHz-2.7GHz
20V/m
Criterion A
Fast transients (Burst)
EN 61000-4-4
Input lines
Output lines
DC-OK signal
(coupling clamp)
4kV
2kV
2kV
Criterion A
Criterion A
Criterion A
Surge voltage on input
EN 61000-4-5
L
→
N
L
→
PE, N
→
PE
2kV
4kV
Criterion A
Criterion A
Surge voltage on output
EN 61000-4-5
+
→
–
+ / –
→
PE
1kV
2kV
Criterion A
Criterion A
Surge voltage on DC-OK
EN 61000-4-5
DC-OK signal
→
PE
1kV
Criterion A
Conducted disturbance
EN 61000-4-6
0.15-80MHz
20V
Criterion A
Mains voltage dips
EN 61000-4-11 0% of 100Vac
40% of 100Vac
70% of 100Vac
0% of 200Vac
40% of 200Vac
40% of 200Vac
70% of 200Vac
0Vac, 20ms
40Vac, 200ms
70Vac, 500ms
0Vac, 20ms
80Vac, 200ms, <4A
80Vac, 200ms, >4A
140Vac, 500ms
Criterion A
Criterion C
Criterion A
Criterion A
Criterion A
Criterion C
Criterion A
Voltage interruptions
EN 61000-4-11 0% of 200Vac (=0V)
5000ms
Criterion C
Powerful transients
VDE 0160
Over entire load range 750V, 0.3ms
Criterion A
Criterion A
The device shows normal operation behavior within the defined limits.
Criterion C
Temporary loss of function is possible. Power supply may shut-down and restarts by itself.
No damage or hazards for the power supply will occur.
EMC Emission
According to the generic standards EN 61000-6-3 and EN 61000-6-4.
Conducted emission
input lines
EN 55011, EN 55022, FCC Part 15, CISPR
11, CISPR 22
Class B
Conducted emission
output lines
IEC/CISPR 16-1-2, IEC/CISPR 16-2-1
Limits for local DC power
networks fulfilled
Radiated emission
EN 55011, EN 55022
Class B
Harmonic input current (PFC) EN 61000-3-2
Fulfilled for Class A equipment
Voltage fluctuations, flicker
EN 61000-3-3
Fulfilled
,
tested with constant
current loads, non pulsing
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
Switching Frequencies
PFC converter
30kHz to 140kHz
Input voltage and output load dependent
Main converter
60kHz to 140kHz
Output load dependent
Auxiliary converter
30kHz to 60kHz
Output load dependent