Protection Features
Output protection
Electronically protected against overload, no-load and short-circuits.
In case of a protection event, audible noise may occur.
Output over-voltage protection Typ. 30.5Vdc
Max. 32Vdc
In case of an internal power supply defect,
a redundant circuit limits the maximum output
voltage. The output shuts down and automatically
attempts to restart.
Degree of protection
IP 20
EN/IEC 60529
Penetration protection
> 4mm
E.g. screws, small parts
Over-temperature protection
Yes
Output shut-down with automatic restart.
The temperature sensor is installed on critical
components inside the unit and turns the unit off
in safety critical situations (e.g. de-rating
requirements not observed, high ambient
temperature, ventilation obstructed or the
mounting orientation de-rating is not followed).
There is no correlation between the operating
temperature and turn-off temperature since
this is dependent on input voltage, load
and installation methods.
Input transient protection
MOV
(Metal Oxide Varistor)
For protection values see chapter 17 (EMC).
Internal input fuse
Included
Not user replaceable slow-blow high-braking
capacity fuse