Pepperl+Fuchs PMI360D-F130-IE8-V15 Manual Download Page 7

PMI360D-F130-IE8-V15

Product Description

20

27

57

 2

02

0-

01

7

4

Product Description

4.1

Use and application

The PMI360D-F130... inductive position measuring system is a high-precision measuring sys

-

tem for non-contact recording of the position of rotary actuators and valves. But, thanks to the 

option of user-friendly and flexible configuration, it is also suitable for universal sensing of 

rotary motions around a fixed center of rotation in all fields of mechanical, system and appara

-

tus engineering.

In addition to its 4 ... 20 mA analog output, the PMI360D-F130... has two independently config

-

urable switching outputs providing two important positions (e.g. start and stop positions).
Furthermore, the "zero point" of the analog output can be selected as desired to balance out 

mechanical ranges, e.g. during mounting. This significantly facilitates both mounting of the 

PMI260D-F130... and subsequent calibration during commissioning.
Mounting the BT-F130-A target (see chapter 4.4) on the sensor housing bore enables position 

sensing. This target rotates in the central bore of the PMI360D-F130 and contains the metal 

insert required for position sensing. It is optimally designed for the mechanical conditions of 

valves or rotary actuators.

Note

The BT-F130-A target can be omitted. If you choose to do so, a metal target must be secured to 

the sensor housing bore. This metal target must meet the material, dimensional and distance 

requirements of the PMI360D-F130... inductive position measuring system.

Summary of Contents for PMI360D-F130-IE8-V15

Page 1: ...PMI360D F130 IE8 V15 Inductive Position Measuring System Manual...

Page 2: ...ion as well as the supplementary clause Expanded reservation of proprietor ship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Page 3: ...s 9 4 4 1 Connection Cables 9 4 4 2 Actuator 9 5 Installation 10 5 1 Note on safety 10 5 2 Mounting 10 5 3 Electrical connection 12 6 Commissioning 13 6 1 Configuration of switching outputs 13 6 2 Con...

Page 4: ...a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the d...

Page 5: ...as developed and manufactured in line with the applicable European standards and directives The product manufacturer Pepperl Fuchs Group 68307 Mannheim Germany has a certified quality assurance system...

Page 6: ...only by trained and qualified personnel It is dangerous for the user to carry out modifications and or repairs and doing so will void the warranty and exclude the manufacturer from any liability In t...

Page 7: ...ions e g start and stop positions Furthermore the zero point of the analog output can be selected as desired to balance out mechanical ranges e g during mounting This significantly facilitates both mo...

Page 8: ...dicate the status during the configuration process and in normal operation The programming buttons serve to configure the position measuring system The middle S0 button is used to configure the zero p...

Page 9: ...t potential for electromagnetic interference please use shielded single ended female cordsets from our extensive range of accessories 4 4 2 Actuator The BT F130 A actuator is designed for mounting dir...

Page 10: ...Check that the actuator is positioned in the center of the sensor so that the actuator does not rub against the sensor housing while the actuator is rotating Warning Risk of short circuit Working on l...

Page 11: ...0 IE8 V15 Installation 202757 2020 01 11 Dimensions and distances A 2 mounting holes length 17 mm B M12 x 1 connector 5 pin Dimension mm a 8 b 23 d 1 2 t 2 10 3 0 3 5 2 10 110 40 76 5 30 41 5 41 5 26...

Page 12: ...ay of ensuring adequate protection against short circuits and or crosstalk 4 Before connecting the cable to the sensor make sure that you have aligned the cores On Pepperl Fuchs connectors the core co...

Page 13: ...ance to the sensor surface see chapter entitled Installation The sensor s green LED lights up 2 Move the target to the desired position at which the S1 switching output is to be active 3 Press the S1...

Page 14: ...on the sensor The sensor s green Power ON LED lights up 3 Move the target to the desired position in which the start point smallest analog value 4 mA of the analog output is to be located 4 Press the...

Page 15: ...middle of target The switching points are set at the factory to the angular positions 30 S1 and 220 S2 You can configure the sensor to locate these switching points at each desired position see chapte...

Page 16: ...a current value of 4 mA When the tar get rotates in the clockwise direction the current increases proportionally to the scanned angle of rotation After precisely one rotation the analog output reaches...

Page 17: ...perties are stable over long periods For this reason regular adjustments to and maintenance on the sensor itself are not necessary Nevertheless check in the course of normal maintenance intervals that...

Page 18: ...de LED does not flash when button is pressed No target mounted Mount the BT F130 A target or your own suitable target Sensor cannot be placed in programming mode LED does not flash when button is pres...

Page 19: ...d Replace the damaged cable lead No output signal at the switch ing output even though asso ciated LED is lit Output cable lead not con nected Connect output cable lead No output signal at the switch...

Page 20: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany 202757 DOCT 1315A...

Reviews: