Output performance in normal operation
20
27
57
2
02
0-
01
15
7
Output performance in normal operation
Example
Figure 7.1
Output performance dependent on the position of the target
1. Marking, angular position 0
°
(factory setting)
2. Position for programming S1 (example)
3. Position for programming S0 (example)
4. Position for programming S2 (example)
5. Output signals
7.1
Performance of S1 and S2 switching outputs
The position of the target is determined by the position measuring system. It is half the target
width (middle of target). The switching points are set at the factory to the angular positions 30
°
(S1) and 220
°
(S2). You can configure the sensor to locate these switching points at each
desired position see chapter 6.1.
The corresponding switching output is activated when the metal target reaches the pro
-
grammed S1 or S2 position. When the metal target is removed from the programmed S1 or S2
position, the switching output returns to the original position. When the metal target leaves the
evaluation range of the position measuring system, an active switching output changes to the
original position ("Up" position), while a non-activated switching output remains unaffected by
this.
S1
S1
S0
S2
S2
360°
270°
180°
90°
0°
6°
6°
S0
S2
S1
S0
5
2
1
3
4