Parameterization
2
019-
03
33
4
Parameterization
The factory default parameters are stored in the OIT memory. You can adjust the parameters
using the Vision Configurator software or the control panel.
Configuration Parameters
Configuration ID
Parameter ID
Value
Description
System
EnableResultPort
0,1
Activates TCP/IP result output
UDP
0,1
Activates UDP result output
PortOut
1
–
65,536
TCP port
PortOutUdp
1
–
65,536
UDP port
SensorName
String
Name of the sensor
ImageTransferActive 0,1 (default: 0)
Activates image transfer if the
sensor is connected. 0 for
RunTime, 1 to set up (with image
display)
ImageTransfer
ALL_IMG
ERROR_IMG
GOOD_IMG
Specify which images should be
transferred to the end device
BadImageTransfer
INSPECT_IMAGE
INSPECT_IMAGE_2
Specify which image should be sent
to the end device if the sensor has
transferred two images in the case
of a fault
Camera
ExposureTime
10
–
20,000 (default: 1500) Exposure time in
s
Gain
0
–
255 (default: 0)
Image gain
StartLive
1
Starts continuous image transfer
mode
StopLive
1
Stops continuous image transfer
mode
CheckImages
0,1
If this is set, the sensor also starts
code sheet detection in continuous
image transfer mode
DisplayPause
100
–
10,000
Delay time before the next image
capture can be started, in ms
Command
TriggerStart
1
Trigger start
GetLastImg
1
Loads the last captured image
GetErrImg
1
Loads the next error image in a
series of up to ten images
SetDefaultParams
1
Loads the default parameters
ResetCounters
1
Sets all internal counters to 0
Control panel
EdgeMode
TRIGGER_EDGE_POS
TRIGGER_EDGE_NEG
Sets the trigger activation according
to the rising or falling edge
TriggerReleaseOption 0,1
If this is set, the sensor waits for an
input signal when activating the
trigger. If this option is disabled, the
input signal of the trigger is ignored