2
019-
03
18
Mounting and Installation
Permissible Reading Window Displacement for CB1 Code Sheets
Figure 3.6
X/Y direction for the displacement of
OIC-xxxx-CB1
code sheets
Reading Windows for OIC-xxxx-CB1 Code Sheets
Code sheet displacement in the X and Y direction
ΔX
ΔY
Reading window in the X and Y direction
X
Y
-200
-150
-100
-50
0
50
100
150
200
Y/mm
Operating distance Z/mm
-200
-150
-100
-50
0
50
100
150
200
X/mm
Operating distance Z/mm
Reading window in the X direction
Reading window in the Y direction
Read range
Read range
300
350
400
450
500
300
350
400
450
500