LUC-M** with HART/4 mA ... 20 mA and PROFIBUS PA
Function group "basic setup" (00)
D
O
C
T
-08
43A
01/
2010
1855
72
20
3.12
Display (008)
The distance measured from the reference point to the product surface and the level
calculated with the aid of the empty alignment are displayed again. Check whether the
values correspond to the actual level or the actual distance. The following cases can
occur:
•
Distance correct – level correct
basic setup completed.
•
Distance incorrect – level incorrect
a further interference echo mapping must be
carried out
"check distance"
(
051)
.
•
Distance correct – level incorrect
check
"empty calibr." (005).
!
Note!
After the basic setup, an evaluation of the measurement with the aid of the envelope
curve (
"evelope curve" (0E)
function group) is recommended.
E
+
–
After 3 s, the following message appears
E
+
–