IDENT-I • IVI-KHD2-4HB5, IVI-KHA6-4HB5
Commissioning an S5 135U with INTERBUS-S interface
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
D
a
te
of
is
su
e
3
0.
07
.2
0
0
1
50
Input data:
IW 20
Mirroring of the command from the analyser unit to the
INTERBUS-S-Master
IW 22
Status/execution counter/head number
K3...1:
Read-head number
N4...1:
4-bit execution counter
S4...1:
Status-/error message
IW 24 and 26
read data
11.7.4 Reading a data medium of type IDC-1k at address 0024h
with read head no. 1 (Auto-Read)
After transmitting the command to the analyser unit, read head no. 1 is switched on.
As soon as a data medium enters the range of read head no. 1, the data are read from
the data medium. The read head is then switched back off.
Output data:
IW 30
Command INTERBUS-S-Master to analyser unit
IW 32
IW 34 ... 36
are not taken into consideration.
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
0
0
0
0
0
0
0
0
0
1
0
0
1
1
T
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-
K3 K2 K1 N4 N3 N2 N1 -
-
-
-
S4 S3 S2 S1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1
0
1
0
0
0
0
0
0
1
0
0
0
0
T
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
0