IUH-F117-V1-*
Operation
Number of Attempts "Tries Allowed" TA
This parameter sets the permitted number of write or read attempts, or outputs the
permitted number of attempts.
Example:
WP1UTA.00.01.01 permits precisely one attempt (= no repeats)
WP1UTA.00.01.03 permits 3 attempts
RP1UTA.00.00 outputs the permitted number of attempts
If the permitted number of write or read attempts between the read/write head and
the tag is increased, this results in:
More reliable reading and writing.
Increased response time.
Number of Unsuccessful Attempts until Status 5 "Enhanced Status 5" E5
This parameter sets the number of unsuccessful read/write attempts until a status
5 is output for an enhanced command, or outputs the number.
Status 0 and status A depend on this parameter, and are output immediately.
Example:
WP1UE5.00.01.05 sets the number to 5 unsuccessful read/write attempts until a
status 5 is output
RP1UE5.00.00 outputs the number
If the number of read/write attempts is reduced:
Faster response time in enhanced mode.
Status 5 messages in the event of unstable tag reading.
ParamTyp:
TA
Default:
TA = 2
Value range:
1 ... 255
ParamTyp:
E5
Default:
E5 = 5
Value range:
0 ... 252