Commissioning
6.1
Definitions
6.1.1
Display
Angle brackets contain the abbreviated meaning of a command structure, e.g.,
<Data>
The index
hex
or .xx denotes a hexadecimal number.
hex
ASCII
denotes a value in the hexadecimal system, specified in ASCII
characters.
Example: 10
dec
corresponds to A
hex
; A
ASCII
corresponds to 41
hex
. see chapter
6.1.2
Legend
<ChanNo>:
IDENT
Control
channel
<CHCK>:
1 byte, 8-bit check sum with the addition of all preceding characters,
without overflow
<Data>:
Data with the size <WordNum> multiplied by 4 bytes
<DataLength>:
Length of the data specified to a command, 2 characters binary,
HighByte, LowByte
eirp:
equivalent isotropically radiated power
erp:
effective radiated power
<ETX>:
1 byte = 03
hex
<read-only code>: TID, 4 bytes + an optional 4 or 8 bytes
<Ldata>:
Length of the data in bytes, 2 bytes
Use in multiframe protocol
<Length>
1 character hex
ASCII
= number of data bytes
Permitted values in the read/write head IUH*: 2, 4, 6, 8, A, C, E
<Luii>:
Length of the UII in bytes, 2 bytes
Use in multiframe protocol
<LogicalOperation>: Links several filters; OR = 0; AND = 1
If one filter only is used, this value is ignored
<MaskData>:
Mask specification
<MaskLength>:
Mask length in bits, values: 00
…
FF
<MemBank>:
Number of the memory bank (see parameter MB)
<ParamTyp>:
Parameter type, 2 bytes, or 2 ASCII characters
<Negate>:
Negates the mask comparison; not negated = 0; negated = 1
<PC>:
Protocol control word according to EPC Gen 2 (ISO/IEC 18000-63), 2
bytes, describes characteristics such as the length of the UI/EPC
<SpecialFixcode>: <PC> & <UII/EPC>
<Status>:
1 ASCII character ()
<StartAddress>:
Start address in the selected memory bank in bits, values: 0000
…
FFFF