Installation
5.4.3
Ground connection
Connect the IDENTControl Compact unit to ground via a screw on the right under the housing.
Connecting the IDENTControl Compact to ground
Screw the ground conductor to the housing with a crimp connector.
5.4.4
Ethernet connection guide
Use the D-coded M12 socket and the V1SD-G-5M-PUR-ABG-V45-G cable to connect the
IDENTControl Compact unit to an Ethernet network.
Note!
In order to guarantee safe grounding, mount the serrated washer between the crimp connector
and the housing.
Use a ground conductor lead with a cross-section of at least 4 mm
2
.
1
Housing
2
Serrated lock washer
3
Crimp connector
4
Lock screw
1
2
4
3
1
Tx+
2
Rx+
3
Tx-
4
Rx-
1
3
4
2
Caution!
Electromagnetic interference
Device malfunction caused by EMC effects.
The M12 socket is connected galvanically to the grounded housing. The EtherNet/IP
specification recommends not using cables with a shield connected to the plug at both ends.
However, we recommend using cables with a continuous shield to avoid malfunctions.